IviACPwrCurrentRamp Extension Group
The IviACPwrCurrentRamp extension group defines extensions for AC power sources with the capability to configure a linear current ramp with a starting and ending current in amps and duration in seconds.
The start current value takes effect immediately then the current ramps linearly to the end current value for the duration specified.
The following figure shows two current ramps. The Start Current of the first ramp is set to the same value as the IviACPwr Current Limit property in IviACPwrBase capability group. The Start Current of the second ramp is set to a value higher than the present IviACPwr Current Limit property, causing an immediate change in current limit before linearly ramping to the End Current value.
IviACPwrCurrentRamp VIs
IviACPwr Query Current Ramp Busy [CR]
IviACPwr Abort Current Ramp [CR]
IviACPwrCurrentRamp Properties
IviACPwr Current Ramp Busy [CR]