IviACPwrFrequencyRamp Extension Group
The IviACPwrFrequencyRamp extension group defines extensions for AC power sources with the capability to configure a linear frequency ramp with a starting and ending frequency in hertz and duration in seconds.
The start freqency value takes effect immediately then the frequency ramps linearly to the end frequency value for the duration specified.
The following figure shows two frequency ramps. The Start Frequency of the first ramp is set to the same value as the IviACPwr Frequency property in IviACPwrBase capability group. The Start Frequency of the second ramp is set to a value higher than the present IviACPwr Frequency property, causing an immediate change in output frequency before linearly ramping to the End Frequency value.
IviACPwrFrequencyRamp VIs
IviACPwr Query Frequency Ramp Busy [FR]
IviACPwr Abort Frequency Ramp [FR]
IviACPwrFrequencyRamp Properties
IviACPwr Frequency Ramp Busy [FR]