IviCounter Configure Frequency Manual
IviCounterBase Capability Group
Configures the IviCounter Frequency Estimate and IviCounter Frequency Resolution properties for a frequency measurement for a particular channel.
resolution (1.0 Hz) Specifies the resolution of the frequency measurement. It is the quantization size,or the smallest delta value that can be detected. The driver sets the IviCounter Frequency Resolution property to this value.
Units: hertz Default Value: 1.0 |
|||
instrument handle The instrument handle you obtain from the IviCounter Initialize VI or IviCounter Initialize With Options VI. The handle identifies a particular instrument session.
Default Value: None |
|||
channel ("") Specifies the name of the channel to configure. The driver sets the IviCounter Frequency Channel property to this value.
Default Value: ""
|
|||
estimate (300 MHz) Specifies the estimated measurement frequency. The driver sets the IviCounter Frequency Estimate property to this value.
Units: hertz Default Value: 300000000.0 |
|||
error in (no error) The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.
The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|||
instrument handle out The instrument handle you obtain from the IviCounter Initialize VI or IviCounter Initialize With Options VI. The handle identifies a particular instrument session.
Default Value: None |
|||
error out The error out cluster passes error or warning information out of a VI to be used by other VIs.
The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |