The IviDigitizerRuntTrigger extension group defines extensions for digitizers with the capability to trigger on runt pulses.

A runt condition occurs when the digitizer detects a positive or negative going pulse that crosses one voltage threshold but fails to cross a second threshold before crossing the first threshold again. The following figure shows both positive and negative runt polarities.

    With the IviDigitizerRuntTrigger extension group, the end-user can select whether a positive runt, negative runt, or either triggers the acquisition.

IviDigitizerRuntTrigger VIs

IviDigitizer Configure Runt Trigger Source

IviDigitizerRuntTrigger Properties

IviDigitizer Runt Trigger Polarity

IviDigitizer Runt Trigger High Threshold