IviDownconverter Error and Warning Codes
The VIs in this driver class generate return values that report the status of this operation.
Status Code Ranges
Status Code Type | Numeric Range (in Hex) |
---|---|
IviDownconverter Errors | 0xBFFA2001 to 0xBFFA3FFF |
IviDownconverter Warnings | 0x3FFA2001 to 0x3FFA3FFF |
Specific Driver Errors | 0xBFFA4000 to 0xBFFA5FFF |
Specific Driver Warnings | 0x3FFA4000 to 0x3FFA5FFF |
IVI Errors | 0xBFFA0000 to 0xBFFA1FFF |
IVI Warnings | 0x3FFA0000 to 0x3FFA1FFF |
Common Instrument Driver Errors | 0xBFFC0000 to 0xBFFCFFFF |
Common Instrument Driver Warnings | 0x3FFC0000 to 0x3FFCFFFF |
VISA Errors | 0xBFFF0000 to 0xBFFFFFFF |
VISA Warnings | 0x3FFF0000 to 0x3FFFFFFF |
The IviDownconverter class driver defines the error codes shown in the following table in addition to the IVI defined error codes.
IviDownconverter Error Codes
Error Codes | Value | Description |
---|---|---|
IVIDOWNCONVERTER_ERROR_TRIGGER_NOT_SOFTWARE | 0xBFFA1001 | The trigger source is not set to software trigger. |
IVIDOWNCONVERTER_ERROR_FREQUENCY_LIST_UNKNOWN | 0xBFFA2001 | The selected frequency list is not defined. |
IVIDOWNCONVERTER_ERROR_MAX_TIME_EXCEEDED | 0xBFFA2002 | Maximum time exceeded before the operation completed. |