Admin Production ni-theme
Current Publication

IviUpconverter IF Input Attenuation

IVI Compliance Package

IviUpconverter IF Input Attenuation

IviUpconverterBase Property

Data Type Access Applies To Coercion High Level VIs
R/W N/A Up IviUpconverter Configure IF Input Attenuation

Description

Specifies the amount of attenuation (or gain) to apply to the active IF input of the upconverter. The units are dB. Positive values for this property represent attenuation while negative values represent gain.

If an instrument only supports a fixed IF attenuation, the driver should accept that value for the IF Input Attenuation property and return Invalid Value error for any other value.

Property Node Path

IviUpconverter»IF Input»IF Input Attenuation