ATTR_DIGWAVEFORM_AUTOSIZE
Type: | Control attribute |
Description: | Determines whether LabWindows/CVI autosizes digital waveform plots based on the height of the graph's plot area. Digital graph plots must be the minimum plot size or larger. The height of the state label font determines the minimum plot size. If the plot area is not large enough to show all the digital lines, LabWindows/CVI does not display lines that would be below the plot area. |
Control Types: | Digital graphs. |
Data Type: | integer |
Default Value: | 1 |
LabWindows/CVI Compatibility: |
LabWindows/CVI 7.1 and later |
Values
0 | False |
1 | True |