Type: Control attribute
Description: Determines how the maximum and minimum values of the scale are calculated when autoscaling is enabled. If ATTR_XLOOSE_FIT_AUTOSCALING is FALSE, the maximum and minimum values of the scale are respectively the largest and smallest value of all plots. If ATTR_XLOOSE_FIT_AUTOSCALING is TRUE, the maximum and minimum values of the scale are calculated in accordance with the value of the ATTR_XLOOSE_FIT_AUTOSCALING_UNIT attribute.

0 = Do not use loose fit

1 = Use loose fit
Control Types: Graphs.
Data Type: integer
Default Value: 0
LabWindows/CVI
Compatibility:
LabWindows/CVI 5.5 and later

Values

0 False
1 True