IviDigitizer Get Trigger Source Name
IviDigitizerBase Capability Group
This VI returns the physical channel identifier that corresponds to the one-based index that the user specifies.
If the value that the user passes for the Source Index parameter is less than one or greater than the value of the IviDigitizer Trigger Source Count property, the VI returns an empty string in the Source Name parameter and returns an error.
instrument handle The instrument handle that you obtain from the IviDigitizer Initialize VI or IviDigitizer Initialize With Options VI. The handle identifies a particular instrument session.
Default Value: None |
|
Source Index (1) A one-based index that defines which name to return.
Default Value: 1 |
|
error in (no error) The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.
The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
instrument handle out The instrument handle that you obtain from the IviDigitizer Initialize VI or IviDigitizer Initialize With Options VI. The handle identifies a particular instrument session.
Default Value: None |
|
Source Name Returns the trigger source name that corresponds to the Index.
The Name buffer must contain at least as many elements as the value you specify with the Name Buffer Size parameter. |
|
error out The error out cluster passes error or warning information out of a VI to be used by other VIs.
The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |