Admin Production ni-theme
Current Publication

Configure Internal Trigger Rate

IVI Compliance Package

IviFgen Configure Internal Trigger Rate

IviFgenInternalTrigger Capability Group

This VI configures the rate at which the function generator's internal trigger source generates trigger signals.

instrument handle The instrument handle that you obtain from the IviFgen Initialize or IviFgen Initialize With Options VI.
error in (no error) The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

trigger rate Specify the rate at which you want the function generator's internal trigger rate to generate trigger signals. The driver sets the IviFgen Internal Trigger Rate [IT] to this value.
instrument handle out The instrument handle that you obtain from the IviFgen Initialize or IviFgen Initialize With Options VI.
error out The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.