Admin Production ni-theme
Current Publication

Disconnect All Channels

IVI Compliance Package

IviSwtch Disconnect All Channels

IviSwtch Base Capability Group

This VI disconnects all paths created since the IviSwtch Initialize VI or IviSwtch Reset VI has been called.

Note  If the switch module is not capable of disconnecting all paths, this VI returns the warning IVISWTCH_WARN_PATH_REMAINS (0x3FFA2001).


instrument handle The instrument handle that you obtain from the IviSwtch Initialize or IviSwtch Initialize With Options VI.
error in (no error) The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

instrument handle out The instrument handle that you obtain from the IviSwtch Initialize or IviSwtch Initialize With Options VI.
error out The error out cluster passes error or warning information out of a VI to be used by other VIs.