To measure frequency, the counter counts the number of crossings of the measured signal through a given level at a given slope. Built-in hysteresis rejects signal noise. Some counters provide autotrigger, which enables them to measure frequency without specifying the level and direction of the crossing.

The counter takes the measurement for a specific amount of time, called the gating time.

The most general triggering scheme for frequency or period measurement is shown in the following figure.

Typical Counter Timer Diagram

IviCounterBase VIs

IviCounter Configure Channel

IviCounter Configure Channel Filter Enabled

IviCounter Configure Channel Level

IviCounter Configure Channel Slope

IviCounter Configure Continuous Totalize

IviCounter Configure Duty Cycle

IviCounter Configure Edge Time

IviCounter Configure Edge Time Reference Levels

IviCounter Configure External Start Arm

IviCounter Configure External Stop Arm

IviCounter Configure Frequency

IviCounter Configure Frequency Manual

IviCounter Configure Frequency Ratio

IviCounter Configure Frequency With Aperture Time

IviCounter Configure Gated Totalize

IviCounter Configure Period

IviCounter Configure Period With Aperture Time

IviCounter Configure Phase

IviCounter Configure Pulse Width

IviCounter Configure Start Arm

IviCounter Configure Stop Arm

IviCounter Configure Timed Totalize

IviCounter Configure Time Interval

IviCounter Fetch Continuous Totalize Count

IviCounter Start Continuous Totalize

IviCounter Stop Continuous Totalize

IviCounter Is Measurement Complete

IviCounter Read

IviCounter Fetch

IviCounter Abort

IviCounter Initiate

IviCounterBase Properties

IviCounter Channel Count

IviCounter Measurement Function

IviCounter Channel Impedance

IviCounter Channel Coupling

IviCounter Channel Attenuation

IviCounter Channel Level

IviCounter Channel Hysteresis

IviCounter Channel Slope

IviCounter Channel Filter Enabled

IviCounter Frequency Channel

IviCounter Frequency Estimate

IviCounter Frequency Resolution

IviCounter Frequency Aperture Time

IviCounter Frequency Estimate Auto

IviCounter Frequency Resolution Auto

IviCounter Period Channel

IviCounter Period Estimate

IviCounter Period Resolution

IviCounter Period Aperture Time

IviCounter Pulse Width Channel

IviCounter Pulse Width Estimate

IviCounter Pulse Width Resolution

IviCounter Duty Cycle Channel

IviCounter Duty Cycle Frequency Estimate

IviCounter Duty Cycle Resolution

IviCounter Edge Time Channel

IviCounter Edge Time Reference Type

IviCounter Edge Time Estimate

IviCounter Edge Time Resolution

IviCounter Edge Time High Reference

IviCounter Edge Time Low Reference

IviCounter Frequency Ratio Numerator Channel

IviCounter Frequency Ratio Denominator Channel

IviCounter Frequency Ratio Numerator Frequency Estimate

IviCounter Frequency Ratio Estimate

IviCounter Frequency Ratio Resolution

IviCounter Time Interval Start Channel

IviCounter Time Interval Stop Channel

IviCounter Time Interval Estimate

IviCounter Time Interval Resolution

IviCounter Phase Input Channel

IviCounter Phase Reference Channel

IviCounter Phase Frequency Estimate

IviCounter Phase Resolution

IviCounter Continuous Totalize Channel

IviCounter Gated Totalize Channel

IviCounter Gated Totalize Gate Source

IviCounter Gated Totalize Gate Slope

IviCounter Timed Totalize Channel

IviCounter Timed Totalize Gate Time

IviCounter Start Arm Type

IviCounter External Start Arm Source

IviCounter External Start Arm Level

IviCounter External Start Arm Slope

IviCounter External Start Arm Delay

IviCounter Stop Arm Type

IviCounter External Stop Arm Source

IviCounter External Stop Arm Level

IviCounter External Stop Arm Slope

IviCounter External Stop Arm Delay

Related Topics

IVI Inherent VIs

IVI Inherent Properties

IviCounterBase Behavior Model